A zSFP+ stacked connector combines two rows of pluggable receptacles and a metal shielding cage in one PCB-mounted assembly. A 2×4 version serves eight ports and a 2×8 version serves sixteen. For a 56 Gb/s PAM4 design, select the exact assembly first. Its port count, compliant-pin footprint, front-panel opening, LED options and signal-integrity model determine whether it fits your board and chassis.
The 56 Gb/s figure is a per-lane interconnect capability for the cited SFP56-class designs. PAM4 uses four amplitude levels and carries two bits per symbol. At a nominal 56 Gb/s line bit rate, the symbol rate is 28 GBd and the baseband Nyquist frequency is 14 GHz, half the symbol rate. This frequency is a reference point for channel analysis. Use the applicable PHY specification for the actual line rate and test bandwidth.
Each SFP56-class port covered here provides one high-speed serial lane in each direction. The reference brochure lists 100GbE applications alongside the 56 Gb/s interconnect rating, without specifying a port aggregation scheme. As a separate PHY example, 100GBASE-CR2 uses two 26.5625 GBd PAM4 lanes at 53.125 Gb/s line rate per lane. Two physical SFP56 ports do not by themselves implement that PHY or create one 100GbE port. Check the host lane architecture, SerDes mode, module or cable, and applicable PHY.
A 2×N assembly places two rows of N ports on one side of the PCB. Select the port count against usable front-panel width and height, extraction access, routing space and airflow. The reference family datasheet lists 2×1, 2×2, 2×4, 2×6, 2×8, 2×10 and 2×12, corresponding to 2, 4, 8, 12, 16, 20 and 24 ports. Confirm availability by exact suffix. For example, the linked inner- and outer-light-pipe drawing contains six row sizes and omits the 2×10 shown in the family datasheet. Other suppliers publish different configurations and options.
Part-level example. Molex 2067418012 is a right-angle 2×8 assembly with 16 ports and 320 loaded circuits, inner light pipes, EMI spring fingers and through-hole compliant-pin termination. Its catalog specifies 0.80 mm mating and termination pitch and a 1.30 mm PCB tail length. The 0.80 mm contact pitch and tail length describe different features. Use the board drawing for port spacing and the manufacturing hole pattern.
These figures come from datasheet 987652-4493 and the cited 2×8 part record. Apply them to those references and use the current drawing and application specification to release your selected assembly.
| Check | Published value and scope |
|---|---|
| PCB and electrical ratings | Family datasheet lists 1.57 mm (0.062 in) minimum PCB thickness for this family and 30 V AC (RMS) or DC maximum. The 2×8 record lists 0.5 A maximum per contact. Verify actual board stack-up limits and system power design. |
| Force and durability | The family brief lists 35 N max PCB insertion, 40 N max mating, 11.5 N max unmating and 100 cycles minimum durability. The PCB insertion entry does not identify a per-pin or per-assembly basis. For press sizing, obtain the force limit or qualified force profile for the exact assembly from the supplier. Use the approved insertion tool, PCB support and shut height. |
| Materials and temperature | The family brief specifies a nickel silver alloy cage, copper-alloy contacts and an operating range of −40 to +85 °C. It lists 0.76 µm (30 µin) minimum gold at the mating area, matte tin at the termination and nickel underplating for the contacts. The 2×8 record gives the matching minimum mating gold thickness as 0.762 µm. Use the module’s own temperature limits in chassis validation. |
![]()
The reference 56G family describes a through-flow cage design, an improved midsection for EMI protection, and vent and light-pipe options. Compare the open airflow area and front-panel interfaces on the actual part drawing. At prototype stage, check module case temperature on both rows with representative loads and fan settings. Include the intended EMI contact surfaces and empty-port hardware in chassis-level EMC verification.
Specify inner or outer light pipes before you place the LEDs or release the panel. The supplier drawing controls the LED pickup and front-panel indicator locations. For example, 2067418012 and 2067418014 are both 2×8 entries, but the drawing specifies inner light pipes on the first and outer light pipes on the second.
![]()
The reference datasheet describes a replacement path for its corresponding 28G 2×N system. Treat this as a starting point for a specific part pairing. Check three interfaces before approving an upgrade or second source:
SFF-8402 provides physical, low-speed electrical and management requirements for the SFP families it covers. Consult the exact connector assembly drawings for switch-board and bezel integration.
For a LINK-PP sourcing or design review, share the incumbent part number and drawing revision, target 2×N port count, target PHY and lane rate, PCB stack-up, bezel drawing, and EMI and light-pipe preferences. Ask for the proposed orderable part, its dimensional drawing and available SI data or samples so your team can qualify the fit and channel.
Browse LINK-PP SFP cage and connector solutions · Request a part-level review
Related guides: